Sign In | Join Free | My himfr.com
Home > Human ELISA Kit >

D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection from wholesalers
     
    Buy cheap D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection from wholesalers
    • Buy cheap D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection from wholesalers

    D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E1004Hu
    Certification : CE, ISO9001:2005, MSDS
    Price : Negotiation
    Supply Ability : Western Union, T/T
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection

    High Specificity Human D-Dimer ELISA Kit for Accurate Quantitative Detection


    Cat.No E1113Hu

    Standard Curve Range: 20pg/ml - 4000pg/ml

    Sensitivity: 10.53pg/ml

    Size: 96 wells

    *This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    Precision

    Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision.

    Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision.

    CV(%) = SD/mean x 100

    Intra-Assay: CV<8%

    Inter-Assay: CV<10%


    Reagent Provided

    ComponentsQuantity
    Standard Solution (4800pg/ml)0.5ml x1
    Pre-coated ELISA Plate12 * 8 well strips x1
    Standard Diluent3ml x1
    Streptavidin-HRP6ml x1
    Stop Solution6ml x1
    Substrate Solution A6ml x1
    Substrate Solution B6ml x1
    Wash Buffer Concentrate (30x)20ml x1
    Biotinylated human D2D Antibody1ml x1
    User Instruction1
    Plate Sealer2 pics
    Zipper bag1 pic

    Material Required But Not Supplied

    • 37°C±0.5°C incubator
    • Absorbent paper
    • Precision pipettes and disposable pipette tips
    • Clean tubes
    • Deionized or distilled water
    • Microplate reader with 450 ± 10nm wavelength filter

    Precautions

    • Prior to use, the kit and sample should be warmed naturally to room temperature 30 minutes.
    • This instruction must be strictly followed in the experiment.
    • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
    • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
    • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
    • Avoid using the reagents from different batches together.
    • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
    • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
    • The kit should not be used beyond the expiration date.

    Reagent Preparation

    All reagents should be brought to room temperature before use.

    Standard Reconstitute the 120μl of the standard (4800pg/ml) with 120μl of standard diluent to generate a 2400pg/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (2400pg/ml) 1:2 with standard diluent to produce 1200pg/ml, 600pg/ml, 300pg/ml and 150pg/ml solutions. Standard diluent serves as the zero standard(0 pg/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:


    2400pg/mlStandard No.5120μl Original Standard + 120μl Standard Diluent
    1200pg/mlStandard No.4120μl Standard No.5 + 120μl Standard Diluent
    600pg/mlStandard No.3120μl Standard No.4 + 120μl Standard Diluent
    300pg/mlStandard No.2120μl Standard No.3 + 120μl Standard Diluent
    150pg/mlStandard No.1120μl Standard No.2 + 120μl Standard Diluent

    Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
    4800pg/ml2400pg/ml1200pg/ml600pg/ml300pg/ml150pg/ml

    Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.


    Summary

    1. Prepare all reagents, samples and standards.

    2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

    3. Wash the plate 5 times.

    4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

    5. Add stop solution and color develops.

    6. Read the OD value within 10 minutes.


    Calculation of Result

    Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

    Product Tags:

    elisa kit

      

    enzyme assay kits

      
    Quality D - Dimer Human Elisa Kit High Specificity For Accurate Quantitative Detection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)