Sign In | Join Free | My himfr.com
Home > Human ELISA Kit >

Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection from wholesalers
     
    Buy cheap Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection from wholesalers
    • Buy cheap Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection from wholesalers

    Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E1559Hu
    Certification : CE, ISO9001:2005, MSDS
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : In Stock
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection

    96 wells High Sensitive ELISA Kit for Human Leptin


    Cat.No E1559Hu

    Standard Curve Range: 0.05ng/ml - 10ng/ml

    Sensitivity: 0.021ng/ml

    Size: 96 wells

    Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.


    Intended Use

    This sandwich kit is for the accurate quantitative detection of human Leptin (also known as LEP) in serum, plasma, cell

    Specimen Collection

    Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

    Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

    Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

    Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

    Tissue Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.


    Assay Procedure

    1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.
    2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.
    3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.
    4. Add 40μl sample to sample wells and then add 10μl anti-LEP antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells (Not blank control well). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.
    5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.
    6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.
    7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.
    8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

    * This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    References

    Cassano S., Pucino V., La Rocca C., Procaccini C., De Rosa V., Marone G., Matarese G.
    Metabolism 63:1272-1279(2014)


    Product Tags:

    enzyme assay kits

      

    elisa kit

      
    Quality Human Leptin Sandwich ELISA Kit for Accurate Quantitative Detection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)