Sign In | Join Free | My himfr.com
Home > Human ELISA Kit >

Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range from wholesalers
     
    Buy cheap Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range from wholesalers
    • Buy cheap Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range from wholesalers

    Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E1559Hu
    Certification : CE, ISO9001:2005, MSDS
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : In Stock
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range

    96 wells High sensitive ELISA Kit for Human Leptin LEP


    * This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    Reagent Provided

    ComponentsQuantity
    Standard Solution (12.8ng/ml)0.5ml x1
    Pre-coated ELISA Plate12 * 8 well strips x1
    Standard Diluent3ml x1
    Streptavidin-HRP6ml x1
    Stop Solution6ml x1
    Substrate Solution A6ml x1
    Substrate Solution B6ml x1
    Wash Buffer Concentrate (30x)20ml x1
    Biotinylated human LEP Antibody1ml x1
    User Instruction1
    Plate Sealer2 pics
    Zipper bag1 pic

    Specimen Collection

    Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

    Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

    Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

    Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

    Tissue Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.


    Reagent Preparation

    Standard Reconstitute the 120μl of the standard (12.8ng/ml) with 120μl of standard diluent to generate a 6.4ng/ml standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (6.4ng/ml) 1:2 with standard diluent to produce 3.2ng/ml, 1.6ng/ml, 0.8ng/ml and 0.4ng/ml solutions. Standard diluent serves as the zero standard(0 ng/ml). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:


    6.4ng/mlStandard No.5120μl Original Standard + 120μl Standard Diluent
    3.2ng/mlStandard No.4120μl Standard No.5 + 120μl Standard Diluent
    1.6ng/mlStandard No.3120μl Standard No.4 + 120μl Standard Diluent
    0.8ng/mlStandard No.2120μl Standard No.3 + 120μl Standard Diluent
    0.4ng/mlStandard No.1120μl Standard No.2 + 120μl Standard Diluent

    Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
    12.8ng/ml6.4ng/ml3.2ng/ml1.6ng/ml0.8ng/ml0.4ng/ml

    Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.


    Cat.No E1559Hu

    Standard Curve Range: 0.05ng/ml - 10ng/ml

    Sensitivity: 0.021ng/ml

    Size: 96 wells

    Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.


    References

    Vuolteenaho K., Koskinen A., Kukkonen M., Nieminen R., Paeivaerinta U., Moilanen T., Moilanen E.
    Mediators Inflamm. 2009:345838-345838(2009)


    Product Tags:

    elisa kit

      

    enzyme assay kits

      
    Quality Leptin / LEP Human ELISA Kit with 0.05ng/ml - 10ng/ml Standard Curve Range for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)