Sign In | Join Free | My himfr.com
Home > Bovine ELISA Kits >

Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision from wholesalers
     
    Buy cheap Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision from wholesalers
    • Buy cheap Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision from wholesalers

    Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E0021Bo
    Certification : CE, ISO9001:2015, MSDS
    Price : Negotiation
    Supply Ability : Western Union, T/T
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision

    High Precision and Sensitivity Bovine Non-esterified Fatty Acid ELISA Assay Kit For Research

    Cat.No E0021Bo

    Reagent Provided

    ComponentsQuantity
    Standard Solution (640μmol/L)0.5ml x1
    Pre-coated ELISA Plate12 * 8 well strips x1
    Standard Diluent3ml x1
    Streptavidin-HRP6ml x1
    Stop Solution6ml x1
    Substrate Solution A6ml x1
    Substrate Solution B6ml x1
    Wash Buffer Concentrate (30x)20ml x1
    Biotinylated Bovine NEFA Antibody1ml x1
    User Instruction1
    Plate Sealer2 pics
    Zipper bag1 pic

    Material Required But Not Supplied

    • 37°C±0.5°C incubator
    • Absorbent paper
    • Precision pipettes and disposable pipette tips
    • Clean tubes
    • Deionized or distilled water
    • Microplate reader with 450 ± 10nm wavelength filter

    Standard Curve Range: 2μmol/L - 600μmol/L

    Sensitivity: 1.17μmol/L

    Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

    *This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    Intended Use

    This sandwich kit is for the accurate quantitative detection of Bovine Non-esterified Fatty Acid (also known as NEFA) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.


    Assay Principle

    This ELISA Assay Kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Bovine NEFA antibody. NEFA present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Bovine NEFA Antibody is added and binds to NEFA in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated NEFA antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Bovine NEFA. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.


    Precautions

    • Prior to use, the ELISA Assay Kit and sample should be warmed naturally to room temperature 30 minutes.
    • This instruction must be strictly followed in the experiment.
    • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
    • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
    • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
    • Avoid using the reagents from different batches together.
    • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
    • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
    • The kit should not be used beyond the expiration date.

    Reagent Preparation

    All reagents should be brought to room temperature before use.

    Standard Reconstitute the 120μl of the standard (640μmol/L) with 120μl of standard diluent to generate a 320μmol/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (320μmol/L) 1:2 with standard diluent to produce 160μmol/L, 80μmol/L, 40μmol/L and 20μmol/L solutions. Standard diluent serves as the zero standard(0 μmol/L). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:


    320μmol/LStandard No.5120μl Original Standard + 120μl Standard Diluent
    160μmol/LStandard No.4120μl Standard No.5 + 120μl Standard Diluent
    80μmol/LStandard No.3120μl Standard No.4 + 120μl Standard Diluent
    40μmol/LStandard No.2120μl Standard No.3 + 120μl Standard Diluent
    20μmol/LStandard No.1120μl Standard No.2 + 120μl Standard Diluent

    Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
    640μmol/L320μmol/L160μmol/L80μmol/L40μmol/L20μmol/L

    Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 600 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.


    Summary

    1. Prepare all reagents, samples and standards.

    2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

    3. Wash the plate 5 times.

    4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

    5. Add stop solution and color develops.

    6. Read the OD value within 10 minutes.


    Calculation of Result

    Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

    Product Tags:

    sandwich elisa kit

      

    elisa test kit

      
    Quality Non - Esterified Fatty Acid Bovine ELISA Kits For Research High Precision for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)